Safe Laser 150

In clinical practice there are three major fields of utilisation of the soft laser effect – pain killing, anti-inflammatory treatment and biostimulation.
Biostimulation: promotes metabolism, assists cell processes, stimulates reproduction, helps immunisation, and increases the number of collagen cells. In short, it promotes self-healing processes. It causes no allergic reactions or harmful electrical or radiation load.
The wave length of the Safe Laser 150 device is 660 nm (red). This is the “therapeutical window” which has several benefits for living tissues.
The diseases witch can be treated with Safe Laser 150
Skin diseases

Skin diseases: 

  • bruise,
  • cut,
  • burn,
  • wounds,
  • chronic inflammation,
  • herpes simplex,
  • herpes zooster,
  • ulcus cruris,
  • non-healing ulcers,
  • multiform exudative erythema,
  • hypertrophic scars,
  • alopecia areata
Oral cavity diseases

 

  • aphta,
  • herpes,
  • chronic inflammation,
  • trigeminus neuralgia,
  • posttraumatic pain,
  • postoperative pain,
  • parodontosis,
  • parodontitis,
  • gingivitis,
  • temporo-mandibular joint lesions,
  • asyalia
Oto-rhino-laryngologic diseases
  • chronic rhinitis,
  • allergic chronic rhinitis,
  • pharyngitis
Ear Complaints
  • inflammation,
  • pain,
  • tinnitus,
  • ear itching
Vascular diseases
  • obliterative vascular diseases,
  • postthrombotic syndrome,
  • ulcus developed  on the ground of varicosity and vasculitis, sicca pregangrenic condition,
  • decubitus
Neurology
  • pain syndromes,
  • degenerative spinal pain,
  • radiculopathies,
  • rehabilitation of those with locomotor disorders,
  • lesions associated with hypertonicity,
  • childhood motility disorders,
  • contractions,
  • Little disease,
  • conditions following brain vascular events (paresis, motility disturbances, flexural contractions) inactivity muscular hypotrophy,
  • atrophy,
  • solution of forced
Musculoskeletal symptoms, rheumatology, sports injuries

Problems in  max. 1,5 cm deep

  • small joint,
  • muscle and tendon injuries, 
  • inflammation,
  • strain,
  • sprain,
  • contusion,
  • abrasion,
  • bruise
  • reumatoid arthritis,
  • arthropathies,
  • arthrosis, other motility organ lesions
Eye Treatment (exclusively on veterinary field):
  • Irradiate the patient’s open eye with the adapter.
  • The time of the treatment is 3 minutes per eye.
  • The threaded adapter can be attached to the head of Safe Laser 150
  • Due to the Safe Laser technology, it is absolutely safe, and it does not damage the eyesightThe following complaints and diseases can be treated with the adapter:
  • Corneal damage
  • Corneal ulcer
  • Inflammation of the conjunctiva (conjunctivitis)
  • Glaucoma
  • Macular degeneration
  • Inflammation of the ciliary body (iridocyclitis)
Laser acupuncture
  • according to the indication circle of the profession

Treatment Time

Skin surface treatment 3 minutes placed on skin
Mouth and ear treatment with fibre optic 1 minute
Nasal treatment with radiation-absorbing head 3 minutes in each nostril

Treatment of acute illnesses (the disease has recently been generated):

  • The treatment should be applied for the first 1-2 weeks every day than three times a week until resolution of symptoms.

Treatment of chronic (prolonged) illness (generated previously 6-8 weeks):

  • The extended period of illness should be treated less often. The first two weeks 3-4 times a week and 2-3 times a week until significant decrease in their symptoms.
  • Chronic (long-standing) diseases to cure naturally take longer (days, weeks, months). After the first treatment, the pain may increase, but this is a temporary phenomenon.
  • With long-term (several months) recovery processes first apply a 10-day daily treatment later a 3-5 occasions a week.
  • A longer-term treatment is not necessarily speed up the healing process, because there is a biological limit, after the cells can’t be further stimulated!Cure with nasal laser irradiation
  • It is recommended for continuous daily use separately for each nostril.

 

  • Eye Treatment (exclusively on veterinary field):
  • Irradiate the patient’s open eye with the adapter.
  • The time of the treatment is 3 minutes per eye.
  • The threaded adapter can be attached to the head of Safe Laser 150

 

Technical data

  • Power: 150mW scattered laser radiation
  • Wave lenght: 660nm laser
  • 2 x 1,5 V DC, 2 x AA batteries
  • Life expectancy: 10.000 hours
  • Short treatment time: 1-3 minutes irradiation
Fibre Optic for Safe Laser 150

szaloptika_safe_laser_150-hez_01szaloptika_safe_laser_150-hez_03

  • Power: 70 mW continuous radiation (fibre optic output)
  • Treatment time: 30 seconds for 4 joule energy
  • Perfect product for dental and ear treatment
  • Easy to fit on Safe Laser 150
Radiation-absorbing Head for Safe Laser 150

sugarszukito_safe_laser_150-hez_01sugarszukito_safe_laser_150-hez_03

  • Power: 25 mW continuous radiation (output of absorbing head)
  • Treatment time: 3 minutes for 4 joule energy
  • Perfect product for nostril and ear treatment
Radiation-absorbing head for Safe Laser 150 for children under 5 year

gyermek_sugarszukito_safe_laser_150-hez_01gyermek_sugarszukito_safe_laser_150-hez_03

  • Power: 25 mW continuous radiation (output of absorbing head)

  • Treatment time: 3 minutes for 4 joule energy
  • Perfect product for nostril and ear treatment
Cosmetic Treatment Head for Safe Laser 150

kozmetikai_kezelo_safe_laser_150-hez_01kozmetikai_kezelo_safe_laser_150-hez_03

  • Increases the absorption of cosmetic ingredients into the deeper tissues
  • Treatment time: 6 minutes
  • Easy to fit on Safe Laser 150
Eye Treatment Adapter for Safe Laser 150 (for veterinary use)

szemkezelo_safe_laser_150-hez_01szemkezelo_safe_laser_150-hez_03

  • Patented optical arrangement safe for eye treatment!

  • Treatment time: 3-3 minutes

  • Easy to fit on Safe Laser 150

  • 50µW/cm2 power density is far less than the safe limits of
    IEC 60825-1:2007) standard

ikon_ctg_kerdezz

Call or send a message!

+36 70 420 1395

hegedus@drlaser.hu

ikon_ctg_kerdezz

Which device is right for your problem?

Information about Safe Laser 150, 500 infra and 1800 infra